Telecommunications (Requirements for Authorised Cabling Products As/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1) (Cth)
Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1)
The AUSTRALIAN COMMUNICATIONS AUTHORITY makes this amendment under subsection 376 (1) of the Telecommunications Act 1997.
Dated
11 December 2002 A.J SHAW Chair
R HORTON Deputy Chair
Australian Communications Authority
1Name of amendment
This amendment is the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1).
2Commencement
This amendment commences on gazettal.
3Amendment of Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001
Schedule 1 amends the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001.
Schedule 1 Amendments
(section 3)
[1] Section 5
omit
AS/ACIF S008:2001.
insert
AS/ACIF S008:2001, modified as set out in Schedule 1.
[2]After section 5
insert
Schedule 1 Modification of AS/ACIF S008:2001
(section 5)
[1]Clause 3, item 29
substitute
[29] IEC 60794–1–2–F5B:1999 Water Penetration Test [2] Clause 5.7.1
substitute
5.7.1 Application
Clause 5.7.2 applies to all types of cabling excluding blown fibre tube systems except where otherwise stated. Other customer cables requirements are specified in Clauses 5.8, 5.9 and 5.10.
[3] Clauses 5.7.2.1 and 5.7.2.2
substitute
5.7.2.1 Cable
5.7.2.1.1 Cables solely intended for telecommunications purposes shall not be of a design or type commonly used for mains power.
5.7.2.1.2 Outdoor cable intended to be installed underground shall comply with the requirements for Water Penetration specified in IEC 60794-1-2–F5B [29].
5.7.2.1.3 Where a recognizable telecommunications cable does not exist or the cable is designed for Multidiscipline use (e.g. designed for special applications such as MIMS cable), the requirements in Clause 5.10 are applicable.
5.7.2.1.4 The outer tube or sheath of an underground blown fibre tube shall comply with —
(a) the requirements of IPX8 of AS 1939 [6]; and
(b) the sheath requirements of Clause 5.7.2.2.2 or Clause 5.7.2.2.3.
5.7.2.2 Insulation and sheath materials
5.7.2.2.1 Telecommunications use
The insulation and sheath materials used shall be suitable for telecommunications use.
5.7.2.2.2 Non-PVC insulation and sheath
Non-PVC insulation and sheath materials shall comply with the requirements of AS 1049 [2] for —
(a) Tensile Strength Test (Aged/Unaged);
(b) Elongation Test (Aged/Unaged);
(c) Shrinkback Tests for that particular type of insulation and sheathing; and
(d) cables exposed to UV radiation for sheath of outdoor cable only.
Compliance with Clause 5.7.2.2.2 (d) is determined by the manufacturer’s declaration.
5.7.2.2.3 PVC insulation and sheath
PVC insulation and sheath materials shall comply with —
(a) the requirements of Table 1 and Table 2; and
(b) the requirements of AS 1049 [2] for cables exposed to UV radiation for outdoor cable only.
Compliance with Clause 5.7.2.2.3 (b) is determined by the manufacturer’s declaration.
0
0
0