Telecommunications (Requirements for Authorised Cabling Products As/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1) (Cth)

Case
No judgment structure available for this case.

Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1)

The AUSTRALIAN COMMUNICATIONS AUTHORITY makes this amendment under subsection 376 (1) of the Telecommunications Act 1997.

Dated   11 December  2002

A.J SHAW  Chair

R HORTON  Deputy Chair

Australian Communications Authority


1Name of amendment

This amendment is the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1).

2Commencement

This amendment commences on gazettal.

3Amendment of Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001

Schedule 1 amends the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001.

Schedule 1          Amendments

(section 3)

[1]          Section 5

omit

AS/ACIF S008:2001.

insert

AS/ACIF S008:2001, modified as set out in Schedule 1.

[2]After section 5

insert

Schedule 1          Modification of AS/ACIF S008:2001

(section 5)

[1]Clause 3, item 29

substitute

[29] IEC 60794–1–2–F5B:1999 Water Penetration Test

[2]          Clause 5.7.1

substitute

5.7.1          Application

Clause 5.7.2 applies to all types of cabling excluding blown fibre tube systems except where otherwise stated. Other customer cables requirements are specified in Clauses 5.8, 5.9 and 5.10.

[3]          Clauses 5.7.2.1 and 5.7.2.2

substitute

5.7.2.1       Cable

5.7.2.1.1     Cables solely intended for telecommunications purposes shall not be of a design or type commonly used for mains power.

5.7.2.1.2     Outdoor cable intended to be installed underground shall comply with the requirements for Water Penetration specified in IEC 60794-1-2–F5B [29].

5.7.2.1.3     Where a recognizable telecommunications cable does not exist or the cable is designed for Multidiscipline use (e.g. designed for special applications such as MIMS cable), the requirements in Clause 5.10 are applicable.

5.7.2.1.4     The outer tube or sheath of an underground blown fibre tube shall comply with —

(a)       the requirements of IPX8 of AS 1939 [6]; and

(b)       the sheath requirements of Clause 5.7.2.2.2 or Clause 5.7.2.2.3.

5.7.2.2       Insulation and sheath materials

5.7.2.2.1     Telecommunications use

The insulation and sheath materials used shall be suitable for telecommunications use.

5.7.2.2.2     Non-PVC insulation and sheath

Non-PVC insulation and sheath materials shall comply with the requirements of AS 1049 [2] for —

(a)       Tensile Strength Test (Aged/Unaged);

(b)       Elongation Test (Aged/Unaged);

(c)       Shrinkback Tests for that particular type of insulation and sheathing; and

(d)       cables exposed to UV radiation for sheath of outdoor cable only.

Compliance with Clause 5.7.2.2.2 (d) is determined by the manufacturer’s declaration.

5.7.2.2.3     PVC insulation and sheath

PVC insulation and sheath materials shall comply with —

(a)       the requirements of Table 1 and Table 2; and

(b)       the requirements of AS 1049 [2] for cables exposed to UV radiation for outdoor cable only.

Compliance with Clause 5.7.2.2.3 (b) is determined by the manufacturer’s declaration.

Actions
Download as PDF Download as Word Document


Cases Citing This Decision

0

Cases Cited

0

Statutory Material Cited

0