Paradise Outdoor Building Company Pty Ltd v Steward

Link copied
Case Copied 56 min read

DISTRICT COURT OF QUEENSLAND

CITATION:  Paradise Outdoor Building Company Pty Ltd v Steward
[2020] QDC 346
PARTIES:  PARADISE OUTDOOR BUILDING COMPANY PTY
LTD
(appellant)
v
SHARON MARIA STEWARD
(respondent)
FILE NO/S:  D31/19
DIVISION: 
PROCEEDING:  s 222 Appeal
ORIGINATING 
COURT: 
Mackay Magistrates Court
DELIVERED ON:  27 November 2020
DELIVERED AT:  Brisbane
HEARING DATE:  26 May 2020
JUDGE:  Dearden DCJ
ORDER:  1. Appeal dismissed.
CATCHWORDS:  CRIMINAL LAW – APPEAL AND NEW TRIAL – DUTY

OF CARE - whether the learned magistrate erred at law in failing to apply and give effect to section 208(1)(a) of the

Electrical Safety Regulation 2013 – whether the learned
magistrate erred in law by not finding that the appellant had
discharged its obligation – whether the learned magistrate

with the obligation in section 68 of the Electrical Safety

erred at law by finding that the appellant failed to comply section 30 of the Electrical Safety Act 2002 (Qld) - whether the learned magistrate erred at law by failing to apply or properly apply the correct standard of proof, namely, beyond

reasonable doubt – whether the learned magistrate erred at
law in failing to give effect to criminal negligence concepts in
the learned magistrate's application of the reasonably
practicable test under section 28 of the Electrical Safety Act

2002 (Qld) – whether the appellant abandoned this ground on the day of the hearing – whether the learned magistrate erred

in law by making a finding that was not reasonably open on the evidence, namely, that it was reasonably practicable for the appellant to undertake further enquiries in relation to the

distance between the power line and the sign – whether the
learned magistrate erred in law by making a finding that was
not reasonably open on the evidence, namely, that the
appellant should have contacted Ergon Energy in relation to
the risk and that the appellant knew or ought reasonably to
have known that it could have done so prior to the incident –
whether the learned magistrate erred in law by making a
finding that was not reasonably open on the evidence,
namely, that had Ergon been informed of the proximity of the
power line to the sign prior to the incident, it would have
arranged to raise the power line – whether the learned
magistrate erred in law by failing to find that an employee
knew that they should have fed the sail track from the bottom
of the sign – whether the learned magistrate erred in law by
not finding that the method of feeding the sail track from the
bottom was a reasonably practicable way to manage risk in
all of the circumstances – whether the learned magistrate
erred in law by making a finding that was not reasonably
open on the evidence, namely, that it was reasonably
practicable to require the appellant to move the sign –
whether the learned magistrate erred in law by making a
finding that was not reasonably open on the evidence, namely
that there was a high risk…
CaseChat AU logo

Keep reading for free

Create a free CaseChat account to read Paradise Outdoor Building Company Pty Ltd v Steward and more:

  • Read every judgment in full
  • Ask AI and get answers linked to paragraphs
  • See how each paragraph was cited in later cases
  • Download judgments as PDF or Word
Continue with Google

One click creates your free account or signs you in.

By continuing you agree to the Terms and Privacy Policy.

Find similar cases

Other decisions on the same topics. Each opens in a new tab.

Details

Case
[2020] QDC 346
Decision Date

CaseChat Overview and Summary

In the case of Paradise Outdoor Building Company Pty Ltd v Steward, the appeal was brought before the Court of Appeal against a decision made by the Magistrates Court. The appellant company was found guilty of breaching its duty under section 40C of the Electrical Safety Act 2002 (ES Act), which mandates that businesses must ensure their operations are conducted in an electrically safe manner. Specifically, the company was found to have failed in its duty to ensure that its workers were not exposed to electrical risk, as they were working near high voltage power lines while handling conductive materials.

The primary legal issue before the Court was whether the evidence supported the conclusion that the appellant company had breached its duty under the ES Act. The appellant argued that it had taken reasonable steps to ensure electrical safety by noting the presence of power lines and implementing processes to feed the sail track from the bottom of the sign. However, the prosecution contended that the company failed to take adequate measures to ensure the safety of its workers, such as contacting the electricity entity to move the power lines, thereby exposing them to electrical risk.

The Court of Appeal conducted a thorough review of the evidence, assessing whether the company had met its duty under the ES Act to ensure electrical safety. The Court concluded that the appellant company had indeed breached its duty by not taking reasonable steps to eliminate the electrical risk, particularly by not contacting the electricity entity to move the power lines. The proximity of the workers to the power lines and the nature of the task they were performing contributed to the risk of electrical injury. Consequently, the Court dismissed the appeal and upheld the original decision of the Magistrates Court.

The final orders of the Court of Appeal were to dismiss the appeal, thereby affirming the decision of the Magistrates Court that Paradise Outdoor Building Company Pty Ltd had breached its duty under the ES Act.

Orders

Orders of the court

1. Appeal dismissed.

Background

Background to the litigation

In Forrest v Commissioner of Police [2017] QCA 132, Sofronoff P stated that:- “…an appellate court hearing an appeal by way of re-hearing must conduct a real review of the evidence and make up its own mind about the case.”[29] [29] Forrest v Commissioner of Police [2017] QCA 132, p.5. Legislative background The legislative background to the charge heard before the learned magistrate has been helpfully summarised by the respondent as follows:- The prosecution case is then conveniently summarised in the respondent’s outline as follows: “21. The Prosecution case was that the Appellant had committed an offence under s40C of the ES Act, by breaching its duty[31] to ensure its business or undertaking was conducted in a way that was electrically safe. The work to be undertaken was not electrically safe,[32] because it was not free from [31] Under s30 of the ES Act. [32] S10(2) ES Act. electrical risk[33] – that is, electrical risk to the company’s workers had not [33] S10(4) ES Act. been eliminated, so far as was reasonably practicable.[34] The proximity of the billboard to the power lines at the time of the incident placed the Appellant’s workers within the 3 metre exclusion zone,[35] which exposed [34] S10(4)(a) ES Act. [35] Regs. 68 and 69 ES Regulation; Code of Practice. the workers to electrical risk.[36] The Prosecution case was that the Appellant company had reasonably practicable means available to it to ensure electrical safety.[37] They had the ability to eliminate the risk by contacting the electricity entity to move the power lines. The Appellant took no steps to contact the electricity entity and made no such enquiries. [36] S10(1) ES Act. [37] S28 ES Act. 22. The evidence at hearing established that the Appellant company had owned the relevant billboard since 1 November 2005.[38] The company’s [38] Trial Exhibit 9. business included changing the advertising skins on advertising signs.[39] On 12 July 2016, an employee of the Appellant company, Mr Nolan, was standing on a ladder attached to the top of a billboard on the verge of the Bruce Highway, Balberra.[40] [39] Admissions [1]. [40] Admissions [2], [3], [6]. 23. He was holding a three metre long aluminium sail track, feeding it down into the sleeve of a canvas advertising skin, when the sail track either contacted or came into close proximity with a 33kVolt overhead electric line, causing an electric shock to Mr Nolan.[41] He suffered significant injuries, most of which were sustained in being thrown from the ladder. He fell over 5 metres to the ground. [41] That Nolan was holding an aluminium sail track, that the sail track was a conductive object, and that he received an electric shock were all admitted and not in issue. 24. The top corner of the billboard was 2.6m from the nearest electric power line.[42] [42] Trial Exhibit 11. 25. The appellant company had identified power lines as being in close proximity to that particular sign during a routine inspection on 5 March 2008.[43] That the power lines were a hazard was then noted on the documentation for that site and the company asserted that it had put in place processes to feed the sail track from the bottom of the sign.[44] The [43] Trial Exhibit 9, letter from Terry McKenzie dated 20 March 2017. [44] Trial Exhibit 9, letter from Terry McKenzie dated 20 March 2017. workers’ documentation on the day in question identified power lines, but did not specifically instruct them to feed the sail track from the bottom. There was no evidence that the company actually knew the sign was within the 3 metre exclusion zone, or that it had conducted any enquiries to find out how close the power lines really were. 26. The Prosecution case was that by requiring its workers, including Mr Nolan, to work in the vicinity of overhead high voltage electrical lines, (particularly within the exclusion zone at the top corner of the billboard), whilst holding a conductive sail track, the Appellant failed to ensure the electrical safety of its workers, and thus breached its duty under s30. The company’s failure exposed workers, including Mr Nolan, to a risk of

Decision

Reasons for decision

Ratio Decidendi

Legal principle established