5(iO2 GOVERNMENT GAZETTE, WA 14 November 2017

C P302

Occupational Safety and Health Act 1984

Occupational Safety and Health Amendment

Regulations 2017

Made by the Governor in Executive Council.

1.       Citation

These regulations are the Occupational Safety and Health
Amendment Regulations 2017.

2.     Commencement

These regulations come into operation as follows —

(a) regulations 1 and 2— on the day on which these

regulations are published in the Gazette (gazettal day);

(b) the rest of the regulations — on the day after the period
of 6 months beginning on gazettal day.
electrical installation has the meaning given in the
Electricity (Licensing) Regulations 1991
regulation 3(1);

3.      Regulations amended

These regulations amend the Occupational Safety and Health
Regulations 1996.

4.      Regulation 1.3 amended

In regulation 1.3 insert in alphabetical order:

14 November 2017 GOVERNMENT GAZETTE, WA 5603

5.            Regulation 3.58 replaced

Delete regulation 3.58 and insert:

3.58. Interpretation

(1) In this Division, unless the contrary intention
appears -
de-energised, in relation to a part of an electrical
installation, has the meaning given in the Electricity
(Licensing) Regulations 1991 regulation 3(1);
electrical work has the meaning given in the Electricity
(Licensing) Regulations 1991 regulation 3(1);
energised, in relation to a part of an electrical
installation, has the meaning given in the Electricity
(Licensing) Regulations 1991 regulation 3(1);
network operator has the meaning given in the
Electricity Act 1945 section 5(1).
(2) For the purposes of this Division, a reference in
AS/NZS 3012 to an electricity distributor is to be
treated as a reference to a person who is a network
operator under the Electricity (Network Safety)
Regulations 2015 regulation 4(1 )(a), (b), (c), (d), (e),
(0 or (g).
(3) For the purposes of this Division -

(a)

a part of an electrical installation is taken to be energised unless it is de-energised; and

(b)

the neutral for a part of an electrical installation is taken to be de-energised if the part is de-energised.

6. Regulations 3.59A and 3.5913 inserted
After regulation 3.59 insert:

3.59A. Electrical work

(1) A person who, at a workplace, is an employer, the main
contractor, a self-employed person, a person having
control of the workplace or a person having control of
access to the workplace must ensure that, before
electrical work is carried out on a part of an electrical
installation at the workplace, the part -
(a) is tested by a competent person to ascertain
whether or not it is energised; and
5604 GOVERNMENT GAZETTE, WA 14 November 2017
(b) if it is found to be energised, is de-energised by
a competent person.

Penalty for this subregulation: the regulation 1.16

penalty.

(2) Subregulation (1)(b) does not apply to electrical work
carried Out under the Electricity (Licensing)
Regulations 1991 regulation 55(2).

3.59B. Work in roof spaces

(1) In this regulation -
building means a Class 1, Class 2 or Class lOa building
as classified under the Building Regulations 2012;
roof space, of a building -
(a) means the space in the building that is -

(i)     immediately under the roof; or

(ii)     if there is a ceiling under the roof, or a part of the roof, the space between the roof, or that part of the roof, and the

ceiling;

but

(b) does not include a habitable room in the roof
space;

service apparatus has the meaning given in the

Electricity Act 1945 section 5(1).

(2) A person who, at a workplace, is an employer, the main
contractor, a self-employed person, a person having
control of the workplace or a person having control of
access to the workplace must ensure that, before work
is done in a roof space of a building at the workplace,
the building's electrical installation is de-energised by
a competent person.
Penalty for this subregulation: the regulation 1.16 penalty.
(3) An employee must not do work in a roof space of a
building at a workplace unless the building's electrical
installation is de-energised by a competent person.
Penalty for this subregulation: the regulation 1.15

penalty.

(4) If the roof space of a building to which
subregulation (2) or (3) applies is divided into separate
parts, such that a person cannot move from 1 part of
the roof space to another, and each part relates to a
separate dwelling, the requirement to de-energise the
building's electrical installation only applies to the
dwelling that relates to the part of the roof space in
which the work is to be done.
14 November 2017 GOVERNMENT GAZETTE, WA 5605

(5)

Subregulations (2) and (3) do not apply to work done by a competent person to test, service or commission an appliance or other equipment in or accessible by

means of the roof space (for example, a gas appliance,
air conditioner or antenna), to the extent necessary to
energise the appliance or equipment, if—
(a) it is necessary to energise the appliance or
equipment for the purpose of testing, servicing
or commissioning the appliance or equipment;
and
(b) a risk assessment has been undertaken in
accordance with regulation 3.1 by a competent
person; and
(c) the competent person referred to in
paragraph (b) is satisfied that -

(i)     the risks identified by the risk assessment are or can be reduced to as low as reasonably practicable; and

(ii)     the work can be carried out safely;

and

(d) if regulation 3.143 does not apply to the work, a
safe work method statement for the work has
been prepared in accordance with
regulation 3.143(4), as if the work were high
risk construction work and the place where the
work is to be carried out were a construction
site.
(6) Subregulations (2) and (3) do not require the
de-energisation of -
(a) service apparatus that is part of a building's
electrical installation; or
(b)

a supply cable that is part of a building's

electrical installation if—

(i)     the cable is from a solar power system, wind turbine or battery; and

(ii)     it is not practicable to de-energise the cable;

or

(c) any other part of a building's electrical
installation if it is not practicable to de-energise
that part.
(7) Subregulations (2) and (3) do not apply to electrical
work carried out under the Electricity (Licensing)
Regulations 1991 regulation 55(2).
5606 GOVERNMENT GAZETTE, WA 14 November 2017

7.      Regulation 3.65 amended

In regulation 3.65 delete "supply authority's- and insert:

network operator's

8. Regulation 3.137 amended
In regulation 3.137 insert in alphabetical order:

energised, in relation to an electrical installation or
line, means connected to a supply of electricity to the
installation or line, whether or not electricity is flowing

through any part of the installation or line;

N. HAGLEY, Clerk of the Executive Council.