Nufarm Limited v Jurox Pty Limited

Link copied
Case Copied 51 min read

FEDERAL COURT OF AUSTRALIA

Nufarm Limited v Jurox Pty Limited [2008] FCAFC 180

PATENTS – infringement – technical terms in claims not defined – experts disagree on meaning and scope of technical terms in patent – claims construed with reference to body of specification including examples – language used in specification indicates that certain examples not within scope of claims – respondent’s product relevantly within excluded examples – no infringement – obviousness – no evidence that those working in the relevant field made themselves familiar with patent specifications

Aktiebolaget Hassle v Alphapharm Pty Limited (2002) 212 CLR 411 cited
Minnesota Mining and Manufacturing Company v Beiersdorf (Australia) Limited (1980) 144 CLR 253 cited

NUFARM LIMITED (ACN 091 323 312) and ARGENTA MANUFACTURING LIMITED v JUROX PTY LIMITED (ACN 000 932 230)

VID 205 OF 2008

LINDGREN, GOLDBERG AND BENNETT JJ
11 NOVEMBER 2008
PERTH (HEARD IN MELBOURNE)


IN THE FEDERAL COURT OF AUSTRALIA

VICTORIA DISTRICT REGISTRY

VID 205 OF 2008

ON APPEAL FROM A SINGLE JUDGE OF THE FEDERAL COURT OF AUSTRALIA

BETWEEN:

NUFARM LIMITED (ACN 091 323 312)
First Appellant

ARGENTA MANUFACTURING LIMITED
Second Appellant

AND:

JUROX PTY LIMITED (ACN 000 932 230)
Respondent

JUDGES:

LINDGREN, GOLDBERG AND BENNETT JJ

DATE OF ORDER:

11 NOVEMBER 2008

WHERE MADE:

PERTH (HEARD IN MELBOURNE)

THE COURT ORDERS THAT:

1.The appeal be dismissed.

2.The appellants pay the respondent’s costs.

Note:    Settlement and entry of orders is dealt with in Order 36 of the Federal Court Rules.


IN THE FEDERAL COURT OF AUSTRALIA

VICTORIA DISTRICT REGISTRY

VID 205 OF 2008

ON APPEAL FROM A SINGLE JUDGE OF THE FEDERAL COURT OF AUSTRALIA

BETWEEN:

NUFARM LIMITED (ACN 091 323 312)
First Appellant

ARGENTA MANUFACTURING LIMITED
Second Appellant

AND:

JUROX PTY LIMITED (ACN 000 932 230)
Respondent

JUDGES:

LINDGREN, GOLDBERG AND BENNETT JJ

DATE:

11 NOVEMBER 2008

PLACE:

PERTH (HEARD IN MELBOURNE)

REASONS FOR JUDGMENT

THE COURT:

  1. Nufarm Limited was the registered proprietor of Australian Innovation Patent No. 2003101020 (‘the Patent’) at the commencement of these proceedings.  Following an assignment of the Patent to Argenta Manufacturing Limited (‘Argenta’), Argenta is the present registered proprietor of the Patent.  The appellants (together ‘Nufarm’) appeal from a decision of the primary judge dismissing their claim of infringement of the Patent by the respondent (‘Jurox’) (Nufarm Ltd v Jurox Pty Ltd (2008) 75 IPR 341). The hearing before the primary judge did not concern the validity of the Patent. Infringement was heard and determined as a separate question. His Honour determined that Jurox’s product, Q-Drench, does not infringe the Patent.

  2. The Patent is entitled “Stable Biocidal Compositions”.  It relates to stable veterinary compositions which are used as an oral drench to control intestinal parasites.  These parasites infect sheep, cattle, goats and other domesticated herbivores.

  3. Claim 1 of the Patent, the relevant independent claim, is as follows:

    A storage stable veterinary composition for oral administration comprising:

    (i)       at least one avermectin as a first active ingredient;

    (ii)at least one organic liquid carrier which carries at least most of…

CaseChat AU logo

Keep reading for free

Create a free CaseChat account to read Nufarm Limited v Jurox Pty Limited and more:

  • Read every judgment in full
  • Ask AI and get answers linked to paragraphs
  • See how each paragraph was cited in later cases
  • Download judgments as PDF or Word
Continue with Google

One click creates your free account or signs you in.

By continuing you agree to the Terms and Privacy Policy.

Find similar cases

Other decisions on the same topics. Each opens in a new tab.

Details

Case
[2008] FCAFC 180
Decision Date

CaseChat Overview and Summary

The case of Nufarm Limited v Jurox Pty Limited was heard in the Federal Court of Australia. The dispute revolves around the interpretation of patent claims concerning a veterinary pharmaceutical composition. The central issue is whether certain formulations described in the patent are emulsions with an organic liquid phase, as claimed, or if they are single-phase micellar solutions. The primary judge’s decision was to be reviewed for any errors in the interpretation of the patent claims and the technical specifications.

The court was tasked with determining whether the primary judge correctly interpreted the patent claims in relation to the chemical formulations described. The primary judge faced the challenge of deciding how to interpret the terms “emulsion” and “organic liquid phase” in light of competing expert opinions. The primary judge did not definitively choose between the conflicting expert opinions but instead considered whether the formulations met the practical criteria for being an emulsion with an organic liquid phase as described in the patent. The court had to consider whether the primary judge's approach to interpreting the patent claims was legally sound and whether the evidence supported the primary judge's conclusion.

The court found that the primary judge appropriately considered the evidence and the competing expert opinions without resolving the abstract theoretical debate over the definitions of the terms “emulsion” and “phase”. Instead, the primary judge focused on whether the formulations in question met the practical description given in the patent claims. The court concluded that the primary judge correctly interpreted the claims and that there was evidence supporting the view that the formulations could be understood as emulsions with an organic liquid phase in the context of the patent's practical application. Therefore, the appeal was dismissed, and the appellants were ordered to pay the respondent’s costs.

Orders

Orders of the court

1. The appeal be dismissed.

2. The appellants pay the respondent’s costs.

Decision

Reasons for decision

LINDGREN, GOLDBERG AND BENNETT JJ
We turn to the decision of the primary judge.THE DECISION OF THE PRIMARY JUDGE There is no issue in the appeal as to the primary judge’s treatment of the background technology of the invention or as to the principles of construction applied by his Honour. Central to the appeal is what his Honour did and did not decide. The primary judge conveniently summarised the problem and the solution as outlined in the specification at [39]:The problem of how to carry all the active ingredients in a single formulation was solved by using water as the carrier for those ingredients (levamisole, benzimidazole and closantel) which do not degrade in water, while separating the ingredient (avermectin) which does degrade in water. Put simply, the composition of the invention utilises a “dual personality” carrier system. It is the effective partitioning of these two environments that forms the basis of the invention described and claimed in the patent specification. The primary judge noted at [59] that there were competing views as to the correct definition of the words “emulsion” and “phase”, as there were about certain other chemical principles and concepts which were relevant to the current dispute. At [59], his Honour summarised those competing views: The dispute between the parties stems from ambiguities which exist as a result of certain wording used in the patent. Fundamentally, those ambiguities reflect a difference of opinions within the relevant audience, namely the skilled addressee, as to the proper meaning of the words “emulsion” and “phase”. I set out below a relatively brief summary of the competing views as to the correct definition of these words, along with some other chemical principles and concepts which are relevant to the current dispute and to the evidence which was given during the course of the trial. As the primary judge observed at [60], theoretically there is no contention about the basic definition of “a phase”, namely that it is ‘any part of a system which is uniform in chemical and physical properties and is separated from other homogenous parts of the system by boundary surfaces’. The debate arises as to the classification of certain examples, which is context-driven depending upon the function of the product. His Honour observed that the parties agreed that an example of a two phase system is olive oil shaken with water, consisting of an oil phase and a water phase. His Honour described the difference between the experts as being whether there was necessarily a threshold in terms of the number of molecules present before a separate phase is formed. This, as his Honour noted at [64], has implications for the interpretation of the term “emulsion” as used in the Patent claims. The primary judge did not, in his discussion of phases at [60]–[63], decide between the conflicting expert opinions. He then turned to discuss the different descriptions of an emulsion. His Honour noted that, while an emulsion may simply be described as a dispersion of one liquid in another or a system in which there is a separation of one liquid phase from another, this raises the question of the difference in the views as to the meaning of “phase”.

Ratio Decidendi

Legal principle established

Established by: LINDGREN, GOLDBERG AND BENNETT JJ

Jurox also raised issues concerning the thermodynamic stability of Q-Drench to support its characterisation as a single phase system.CONSIDERATION There was evidence, which his Honour was entitled to accept, that the construction advanced by Jurox was consistent with the way in which the skilled reader would understand the terms as used in the specification. That evidence was to the effect that examples 1 to 4 are single phase micellar solutions which could be described as completely aqueous formulations lacking an organic liquid phase in which abamectin is solubilised in micelles mainly consisting of molecules of Tween 80 together with molecules of benzyl alcohol, propylene glycol and water. Whether or not, strictly speaking, those formulations could also be characterised as emulsions is not to the point. Nufarm accepts that there is no universally held view of the limit to the range of emulsions. There was a great deal of evidence before the primary judge as to the meaning that should be given to the word “emulsion” and as to whether or not it includes micellar solutions and microemulsions. There was also evidence as to the role of thermodynamic stability in the characterisation of an emulsion, because a commonplace definition of emulsion is in terms of a thermodynamically unstable system. There was no universal acceptance in the evidence as to whether microemulsions are one phase or two phase systems. For example, Professor Tucker was of the view that thermodynamically stable microemulsions are one phase systems. There was evidence, including evidence of Nufarm witnesses, that most people in the industry would regard a microemulsion as a single phase system. The evidence also indicated that the term “microemulsion” may be used to describe swollen micelles containing an internal phase like a solubilised solution. Microemulsions may also appear as clear transparent solutions but unlike micellar solubilised systems, microemulsions may not be thermodynamically stable. They have been characterised as intermediate between thermodynamically stable solubilised solutions and ordinary emulsions which are relatively unstable. His Honour appreciated that, as at the priority date, there were different views as to what was included in the definition of an emulsion. However, the primary judge did not decide the case by determining the scope of the meaning of the terms “emulsion” or “organic phase” in a theoretical or abstract sense. His Honour recognised the difficulty of adopting that course in circumstances where expert opinion was divided. Rather, armed with an understanding derived from the explanations of the persons of skill in the art, his Honour considered whether Q-Drench (within the formulations of examples 1 to 4) was an “emulsion” with an “organic liquid phase” within the meaning of the claims (at [97]-[99], [113], [118] and [135]). For this purpose his Honour looked to the body of the specification, which explained that:·The point of the formulations was to protect the abamectin from the water;·The low pH of the formulations in examples 1 to 4 made them unsuitable for the long-term stability of the abamectin;·This was because the abamectin was not sufficiently separated in those formulations from the water;·A vegetable oil was added after example 4 to encapsulate the abamectin and possibly protect it from the low pH of the water phase.