Gas Standards (Natural Gas) Regulations 1999 (WA)
Western Australia
Gas Standards Act 1972
These regulations were repealed by the
Western Australia
Western Australia
Gas Standards Act 1972Gas Standards Act 1972
These regulations may be cited as the
These regulations come into operation on 1 May 1999.
In these regulations —
(a) an undertaker;
(b) a pipeline licensee;
(c) an operator of a reticulated gas supply system; or
(d) a person who supplies gas through a pressurized container;
(1) A gas supplier must ensure that natural gas distributed to a consumer through gas mains and service lines or used for domestic purposes in compressor plants —
(a) has a Wobbe index that is not more than 51.0 and not less than 46.5;
(b) is free by normal commercial standards from dust and other solid or liquid matters, waxes, gums and gum forming constituents, aromatic hydrocarbons and radioactive components that might cause injury to or interfere with the proper operation of the equipment through which it flows;
(c) does not have a total sulphur content exceeding 50 mg per cubic metre of the gas;
(d) has a higher heating value produced by combustion of the gas of not less than 37.0 and not more than 41.0 megajoules per cubic metre of the gas;
(e) is odorized in accordance with regulation 5; and
(f) is subject to periodic sampling to determine the effectiveness of the odorizing.
(2) The gas supplier must ensure that records are kept of all sampling conducted under subregulation (1)(f).
(3) In this regulation —
Natural gas must be odorized by the addition to the gas of an odorant, the nature and rate of which is approved from time to time by the Director so that —
(a) the gas has a distinctive, unpleasant and non‑persistent odour; and
(b) when the gas is discharged, the odour indicates throughout its discharge the presence of gas down to the lower explosive limit.
Despite regulation 4(1)(e) the Director may, in a particular case or class of case, permit a gas supplier to distribute gas that is not odorized if —
(a) the gas is to be delivered for further processing or use; and
(b) the odorant would serve no useful purpose as a warning agent.
27 Apr 1999 p. 1789-90 | 1 May 1999 (see regulation 2) | |
gas supplier....................................................................................................................... 3
higher heating value.................................................................................................... 4(3)
ISO.................................................................................................................................. 4(3)
natural gas......................................................................................................................... 3
Wobbe index................................................................................................................. 4(3)
0
0
0