Clean Air (Determination of Air Impurities in Gases Discharged to the Atmosphere) Regulations 1983 (WA)
Western Australia
Environmental Protection Act 1986 2
Reprinted under the Reprints Act 1984 as at 18 March 2005
Western Australia
Reprinted under the Reprints Act 1984 as at 18 March 2005
Western Australia
Environmental Protection Act 1986 2Environmental Protection Act 1986
These regulations may be cited as the
In these regulations unless the contrary intention appears —
For the purposes of section 33(1) of the Act
(a) any boiler or incinerator emitting solid particles — the standard of concentration at the point of emission determined in accordance with regulation 4(2), of solid particles in residual gases, adjusted to a basis of 12% carbon dioxide shall be 0.25 g/m
3 ;(b) any other trade, industry, process, industrial plant or fuel burning equipment emitting solid particles not mentioned in paragraph (a) — the standard of concentration at the point of emission, determined in accordance with regulation 4(2) of these regulations of solid particles in residual gases before admixture with air, smoke or other gases shall be 0.25 g/m
3 .
(1) The standard of concentration of solid particles in each cubic metre of residual gas at the point of emission shall be determined in the following manner — the sample of solid particles entrained in the exhaust gas shall be withdrawn from the flue or chimney in such a way that the velocity of the gases entering a sample nozzle placed in the flue or chimney is, as nearly as practicable the same as the velocity of the gases flowing in the flue or chimney at the sampling point.
(2) For the purposes of section 33(1) of the Act
3 the prescribed point is a point —(a) that is not less than —
(i) 2D away from a bend or change in direction of the gas flow; and
(ii) 3D away from a fan or damper,
where D is the diameter of the flue, or in the case of a rectangular flue, D is the mean of its width and breadth;
(b) at which the average gas velocity is greater than 3 metres per second; and
(c) that is downstream of any dust control equipment.
(3) To collect a representative sample of solid particles, increments of sample shall be withdrawn from the flue at points contained in the sampling plane at the prescribed point of emission.
(4) The number of sampling points shall be —
(a) not less than 4 for duct areas smaller than 0.20 square metres;
(b) not less than 8 for duct areas between 0.20 and 2.0 square metres; and
(c) not less than one for each 0.25 square metres of the sampling plane for duct areas larger than 2.0 square metres,
and the sampling points shall be at the centre of equal areas over the sampling plane.
(5) The sampling time is to be the same for each sampling point, and, shall not in any case be less than 3 minutes.
(6) The sample of solid particles is to be separated from the gas by a filter of fibreglass, alundum or some other suitable material which will withstand the conditions existing at the sampling position.
(1) The method by which it is ascertained that smoke is dark smoke is by the use of a Ringelmann Chart or Miniature Ringelmann Chart.
(2) The chart is to be held or fixed in a position facing the observer and is to be in line with the observer and the source under observation.
(3) The darkness of the air impurities at the point where they leave the source is to be compared with the shades on the chart.
(4) The shade which most closely matches the darkness of the air impurities and the time of the duration of this shade are to be noted.
(5) As far as practicable, when observations are made with the sun shining, the position of the observer and the chart is to be such that the sun, chart and observer form a right angle.
(6) When the Ringelmann Chart is used, the observer is to be 15 to 30 metres from the chart and when the Miniature Ringelmann Chart is used, the observer is to be 1 to 5 metres from the chart.
(7) The Ringelmann Chart and Miniature Ringelmann Chart used for making the measurements described in this regulation shall correspond to charts held by the Minister certified as the standard charts under the signature of the Minister.
13 May 1983 p. 1436‑7 | 13 May 1983 | |
21 Jun 1985 p. 2201‑2 | 21 Jun 1985 (see r. 2 and | |
boiler.................................................................................................................................. 2
cubic metre........................................................................................................................ 2