AD/G1159/44 Adel Wiggins Floor Heater Pad System (Cth)

Case
No judgment structure available for this case.

AIRWORTHINESS DIRECTIVE

For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.001(1) of CASR 1998.  The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.

Gulfstream (Grumman) G1159 and G-IV Series Aeroplanes

AD/G1159/44 Adel Wiggins Floor Heater Pad System 11/2005 DM

Applicability:

Gulfstream Aerospace Corporation model/series aeroplanes as follows:

Model/Series

G-IV
GIV-X
GV
GV-SP

Serial Numbers

All
4001 through 4023 inclusive
All
5001 through 5075 inclusive

Requirement:

1.    Perform an inspection to determine if an Adel Wiggins floor heater pad system is installed.  A review of aeroplane maintenance records is acceptable in lieu of this inspection if the presence of Adel Wiggins floor heater pads can be conclusively determined from that review.

2.    If an Adel Wiggins floor heater pad system is found during the Requirement 1 inspection/determination - deactivate the Adel Wiggins floor heater pad system in accordance with the Accomplishment Instructions of the applicable Alert Customer Bulletin (ACB) identified below, unless Requirement 3 applies.

Model/Series


G-IV
GV
G-IV (G300)
GIV-X (G350
G-IV (G400)
GIV-X (G450)
GV-SP (G500)
GV-SP (G550)

ACB, including Gulfstream
drawing 1159SB50018

   G-IV ACB 33
GV ACB 22
G300 ACB 33
G350 ACB 2
G400 ACB 33
G450 ACB 2
G500 ACB 3
G550 ACB 3

Date


13 June 2005
13 June 2005
13 June 2005
13 June 2005
13 June 2005
13 June 2005
13 June 2005
13 June 2005

3.    For any aeroplane that is found to have an Adel Wiggins floor heater pad system installed but is not listed in the effectivity block of Gulfstream Drawing 1159SB50018, deactivate the Adel Wiggins floor heater pad system in accordance with a method approved by the Manager, Atlanta Aircraft Certification Office (ACO), FAA.

Note 1:  For details of deactivation method approved by the Atlanta FAA ACO contact Gulfstream Customer Support on +1 912-965-4178 for assistance.

Note 2:  FAA AD 2005-16-14 Amdt 39-14220 refers.

Compliance:

For Requirements 1, 2 and 3 - Within 25 flight hours or 30 days after the effective date of this Directive, whichever occurs first.

This Airworthiness Directive becomes effective on 2 September 2005.

Background:

The United States Federal aviation Administration has received a report of an incident in which an Adel Wiggins floor heater pad system short-circuited on a Gulfstream GV-SP series aeroplane.  The short-circuit was discovered after an odour of burning was detected emanating from the floor of the cabin.  The short-circuit resulted in localized damage to the floorboard and carpet.  No circuit breakers tripped as a result of the short-circuiting.  This condition, if not corrected, could result in a fire in the aeroplane cabin.

Adel Wiggins floor heater pad systems may also be installed on all Gulfstream Model G-IV and G-V series aeroplanes and certain Gulfstream Model GIV-X series aeroplanes.  Therefore, those models may be subject to the unsafe condition revealed on Model GV-SP series aeroplanes.

This Directive requires a one-time inspection to determine if an Adel Wiggins floor heater pad system is installed and deactivation of the floor heater pad system if it is installed.


Charles Lenarcic
Delegate of the Civil Aviation Safety Authority

29 August 2005