Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1)

Administered by Department of Communications and the Arts

Legislation au F2005B00324 Not in force Legislative Instrument

Legislation content

Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1)

The AUSTRALIAN COMMUNICATIONS AUTHORITY makes this amendment under subsection 376 (1) of the Telecommunications Act 1997.

Dated   11 December 2002

A.J SHAW                                                                                                                Chair

R HORTON                                                                                                           Deputy Chair

 

Australian Communications Authority

 

1 Name of amendment

  This amendment is the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Amendment Technical Standard 2002 (No. 1).

2 Commencement

  This amendment commences on gazettal.

3 Amendment of Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001

  Schedule 1 amends the Telecommunications (Requirements for Authorised Cabling Products AS/ACIF S008:2001) Technical Standard 2001.

Schedule 1 Amendments

(section 3)

Do not delete: Schedule Part Placeholder

[1] Section 5

omit

AS/ACIF S008:2001.

insert

AS/ACIF S008:2001, modified as set out in Schedule 1.

[2] After section 5

insert

Schedule 1 Modification of AS/ACIF S008:2001

(section 5)

[1] Clause 3, item 29

substitute

 

[29]

IEC 60794–1–2–F5B:1999

Water Penetration Test

[2] Clause 5.7.1

substitute

5.7.1 Application

 Clause 5.7.2 applies to all types of cabling excluding blown fibre tube systems except where otherwise stated. Other customer cables requirements are specified in Clauses 5.8, 5.9 and 5.10.

[3] Clauses 5.7.2.1 and 5.7.2.2

substitute

5.7.2.1 Cable

5.7.2.1.1 Cables solely intended for telecommunications purposes shall not be of a design or type commonly used for mains power.

5.7.2.1.2 Outdoor cable intended to be installed underground shall comply with the requirements for Water Penetration specified in IEC 60794-1-2–F5B [29].

5.7.2.1.3 Where a recognizable telecommunications cable does not exist or the cable is designed for Multidiscipline use (e.g. designed for special applications such as MIMS cable), the requirements in Clause 5.10 are applicable.

5.7.2.1.4 The outer tube or sheath of an underground blown fibre tube shall comply with 

 (a) the requirements of IPX8 of AS 1939 [6]; and

 (b) the sheath requirements of Clause 5.7.2.2.2 or Clause 5.7.2.2.3.

5.7.2.2 Insulation and sheath materials

5.7.2.2.1 Telecommunications use

 The insulation and sheath materials used shall be suitable for telecommunications use.

5.7.2.2.2 Non-PVC insulation and sheath

 Non-PVC insulation and sheath materials shall comply with the requirements of AS 1049 [2] for 

 (a) Tensile Strength Test (Aged/Unaged);

 (b) Elongation Test (Aged/Unaged);

 (c) Shrinkback Tests for that particular type of insulation and sheathing; and

 (d) cables exposed to UV radiation for sheath of outdoor cable only.

 Compliance with Clause 5.7.2.2.2 (d) is determined by the manufacturer’s declaration.

5.7.2.2.3 PVC insulation and sheath

 PVC insulation and sheath materials shall comply with 

 (a) the requirements of Table 1 and Table 2; and

 (b) the requirements of AS 1049 [2] for cables exposed to UV radiation for outdoor cable only.

 Compliance with Clause 5.7.2.2.3 (b) is determined by the manufacturer’s declaration.

 