Application for Variation of a Pipeline Licence - Pipeline Licence VIC/PL43 (HHG9ZC)

Administered by Department of Industry, Science and Resources

Legislation au C2025G00470 In force Gazette

Legislation content

 

COMMONWEALTH OF AUSTRALIA 

 

Sections 226 and 708 

Offshore Petroleum and Greenhouse Gas Storage Act 2006  

 

APPLICATION FOR VARIATION OF A PIPELINE LICENCE - PIPELINE LICENCE VIC/PL43 (HHG9ZC) 

 

I, STEVEN ROBERT TAYLOR, delegate of the National Offshore Petroleum Titles Administrator, on behalf of the Commonwealth – Victoria Offshore Petroleum Joint Authority hereby give notice pursuant to sections 226 and 708 of the Offshore Petroleum and Greenhouse Gas Storage Act 2006 that an application has been received from 

 

 

Cooper Energy (Sole) Pty Ltd 

 ACN 613 951 429 

 

 

for the variation of Pipeline Licence VIC/PL43 in the offshore area of Victoria, as set out below.  

 

Pursuant to subsection 226(3) of the Act, a person may make a written submission to the Titles Administrator about this application within 30 days from the date of this notice.  

 

This notice takes effect on the day on which it appears in the  
Australian Government Gazette. 

 

Made under the Offshore Petroleum and Greenhouse Gas Storage Act 2006 

of the Commonwealth of Australia. 

 

STEVEN ROBERT TAYLOR 

DELEGATE OF THE TITLES ADMINISTRATOR 

ON BEHALF OF THE COMMONWEALTH–VICTORIA 

OFFSHORE PETROLEUM JOINT AUTHORITY 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

APPLICATION FOR VARIATION OF  

PIPELINE LICENCE VICPL43 

 

The Basis of Design is varied by updating the items in bold and italics: 

 

Basis of Design 

 

Item 

Item Description 

Details 

1 

Outside diameter of pipe  

12” rigid pipeline: 305 mm 

2 

Wall thickness of pipe 

12” rigid pipeline: 17–19.4 mm  

3 

Length 

57.96 km (approximate) 

4 

Design life 

15 years (approximate) 

5 

Pipeline Material 

Carbon Steel 

6 

Pipeline Steel Grade 

DNV-OS-F101 Grade 450 

7 

Pipeline Specification 

DNV-OS-F101 Seamless 

8 

Minimum yield strength of pipe steel 

450 MPa  

9 

Maximum Allowable Operating Pressure 

12” rigid pipeline: 13.2 MPa 

6” tie-in spools: 13.2 MPa 

10 

Maximum Design Capacity 

Gas flow: 81 MMscf/d 

11 

Maximum Operating Temperature 

12” rigid pipeline: 40°C 

6” tie-in spools: 40°C 

12 

Maximum Design Temperature 

12” rigid pipeline: 50°C 

6” tie-in spools: 50°C 

13 

Minimum Design Temperature 

12” rigid pipeline: 0°C 

6” tie-in spools: -10°C 

14 

Characteristics of substance proposed to be conveyed 

Gas and condensate. 

15 

General plans and descriptions of pump stations, tank stations or valve stations and their equipment 

N/A 

16 

General plans and description of pigging facilities 

Temporary pig launchers and receivers will be installed at the PLEM. 

17 

Cathodic Protection 

External corrosion management shall be via a low profile sacrificial cathodic anode system. Bracelet anodes, positioned approximately every 24 joints, will be connected via doubler plates welded to the pipeline. The system is designed to be maintenance free and monitored via ROV inspection and measurement where required as part of regulatory surveys. Anode design and supply will be in accordance with DNV-RP-F103. 

 

The existing ROUTE OF THE PIPELINE, SPECIFICATIONS – Design and Construction and SOLE PIPELINE ROUTE (ATTACHMENT 1) remains as stated in the licence instrument dated 4 April 2018 and as varied 13 May 2020 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.