Application for Grant of a Pipeline License – Crux (WA)

Administered by Department of Industry, Science and Resources

Legislation au C2022G00057 In force Gazette

Legislation content

 

COMMONWEALTH OF AUSTRALIA

 

Section 708

Offshore Petroleum and Greenhouse Gas Storage Act 2006

 

APPLICATION FOR GRANT OF A PIPELINE LICENCE – CRUX (WA)

 

I, GRAEME ALBERT WATERS, the National Offshore Petroleum Titles Administrator, on behalf of the Commonwealth–Western Australia Offshore Petroleum Joint Authority hereby give notice pursuant to section 708 of the Offshore Petroleum and Greenhouse Gas Storage Act 2006 that an application has been received from

 

Shell Australia Pty Ltd

(ACN 009 663 576)

 

SGH Energy WA Pty Ltd

(ACN 113 911 274)

 

Osaka Gas Crux Pty Ltd

(ACN 126 767 093)

 

for the grant of a pipeline licence for the conveyance of petroleum in the offshore area of Western Australia, as set out below.

 

A person may make a written submission to the Titles Administrator about this application within 30 days from the date of this notice.

 

This notice takes effect on the day in which it appears in the

Australian Government Gazette.

 

Made under the Offshore Petroleum and Greenhouse Gas Storage Act 2006

of the Commonwealth of Australia.

 

GRAEME ALBERT WATERS

TITLES ADMINISTRATOR

ON BEHALF OF THE COMMONWEALTH-WESTERN AUSTRALIA

OFFSHORE PETROLEUM JOINT AUTHORITY

 

 

 

 

 

 

 

 

 

ROUTE OF THE PIPELINE

 

The pipeline route is described in the table hereunder and displayed in the attached map (Attachment 1), commencing at the boundary of the Territory of Ashmore and Cartier Islands and Western Australia offshore areas to the Upstream Flange Riser Emergency Shutdown Valve (RESDV) on Prelude FLNG. Coordinates are based on Geodetic Datum of Australia (GDA94), UTM Zone 51*.

Feature ID

Feature Name

KP

Easting

(mE)

Northing

(mN)

Heading

Radius (m)

1

Boundary of the Territory of Ashmore and Cartier Islands and Western Australia offshore areas

78.708

589 032.93

8 526 855.43

232.64

 

2

TP7A

89.295

580 618.17

8 520 430.95

232.64

 

3

IP7

 

580 485.86

8 520 329.93

 

3000

4

TP7B

89.628

580 365.53

8 520 214.90

 

 

5

TP8A

114.836

562 145.09

8 502 795.23

226.29

 

6

IP8

 

561 905.47

8 502 566.13

 

1500

7

TP8B

115.488

561 591.61

8 502 459.37

 

 

8

TP9A

117.780

559 422.13

8 501 721.35

251.21

 

9

IP9

 

559 072.26

8 501 602.32

 

1500

10

TP9B

118.504

558 817.72

8 501 334.39

 

 

11

TP10A

126.360

553 407.38

8 495 639.34

223.53

 

12

IP10

 

553 243.31

8 495 466.62

 

1500

13

TP10B

126.832

553 140.81

8 495 251.57

 

 

14

TP11A

129.418

552 028.34

8 492 917.44

205.48

 

15

IP11

 

551 910.06

8 492 669.26

 

1500

16

TP11B

129.962

551 711.44

8 492 479.17

 

 

17

TP12A

145.832

540 245.96

8 481 505.31

226.26

 

18

IP12

 

539 911.48

8 481 185.16

 

3000

19

TP12B

146.751

539 496.03

8 480 980.76

 

 

20

WA-2-IL Boundary

151.514

535 222.02

8 478 877.88

 

 

21

TP13A

151.721

535 037.23

8 478 786.96

243.80

 

22

IP13

 

534 213.72

8 478 381.79

 

1500

23

TP13B

153.368

534 199.61

8 477 464.11

 

 

24

Prelude PLET SSIV

154.350

534 184.59

8 476 486.75

 

 

25

Prelude PLET hub face

154.360

534 184.36

8 476 472.05

180.88

 

26

Prelude Flexible Riser

Approximate total length 900m

 

 

27

Upstream Flange RESDV on Prelude FLNG**

 

534 322.46

8 475 877.88

 

 

*   Coordinates in the map at Attachment 1 are displayed in GDA2020, UTM Zone 51.

** Coordinates are approximate and based on the Prelude FLNG turret centre nominal position, which may move slightly based on sea states and weather.


SPECIFICATIONS

 

Design and Construction

 

The offshore pipeline must be designed and constructed in accordance with Offshore Standard DNVGL-ST-F101 – Submarine Pipeline Systems (Offshore Pipeline), which is incorporated in its entirety in Australian Standard AS2885.4 – Pipelines, Gas and Liquid Petroleum (Part 4: Submarine Pipelines). Specifically, the design and construction phase of the pipeline must comply with DNVGL-ST-F101.

 

Basis of Design

 

The pipeline design is based on the following parameters:

 

Item

Item Description

Details

1

Outside diameter of pipe and riser

26” Crux export pipeline: 26 inches (660.5 mm) nominal

Prelude PLET (including reducer & SSIV):18 inches (457.2 mm) nominal

2

Wall thickness of pipe inclusive of riser (only for carbon steel)

26” Crux export pipeline: 19.1 mm

Prelude PLET (including reducer & SSIV): 25.4 mm

16” ID Prelude flexible riser (total of all layers): ~82.5 mm

3

Length

76.6 km (approximate)

4

Design life

20 years (approximate)

5

Pipeline Material

Flexible steel

6

Pipeline and Riser Steel Specification and Grade

DNVGL-ST-F101 SAWL Gr 450 DF

API Spec 17J Specification for Unbonded Flexible Pipe

API Spec 17J Rough Bore Flexible Pipe Composition

7

Minimum yield strength of pipe steel

450 MPa

8

Maximum Allowable Operating Pressure

133 barg

9

Design Capacity

550 MMscf/d

10

Maximum Design Temperature

27” Crux Export Pipeline and Prelude PLET (including reducer & SSIV): 70⁰C

16” ID Prelude Flexible Riser: 70⁰C

11

Minimum Design Temperature

27” Crux Export Pipeline and Prelude PLET (including reducer & SSIV): -3⁰C

16” ID Prelude Flexible Riser: -20⁰C

12

Maximum Operating Temperature

27” Crux Export Pipeline and Prelude PLET (including reducer & SSIV): 55⁰C

16” ID Prelude Flexible Riser: 50⁰C

13

Characteristics of substance proposed to be conveyed

Dehydrated gas and condensate

14

General plans and descriptions of pump stations, tank stations or valve stations and their equipment

N/A

15

General plans and description of pigging facilities

Pig launcher is located on Crux platform, and pig received is located on Prelude FLNG, pigging facilities are not within the pipeline licence boundary

16

Cathodic protection

Al-Zn-In alloy anodes.

Bracelet type, full shell, non-tapered. 600mm length x 50mm thickness (163kg) installed at various locations along the pipeline.

Anodes attached directly to the PLET structure.

Bracelet type at each end of the flexible riser.

 

 


Attachment 1

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.