COMMONWEALTH OF AUSTRALIA
Section 708
Offshore Petroleum and Greenhouse Gas Storage Act 2006
APPLICATION FOR GRANT OF A PIPELINE LICENCE (JDP3-JULB Pipeline) – OFFSHORE AREA OF WESTERN AUSTRALIA
I, GRAEME ALBERT WATERS, the National Offshore Petroleum Titles Administrator, on behalf of the Commonwealth–Western Australia Offshore Petroleum Joint Authority hereby give notice pursuant to section 708 of the Offshore Petroleum and Greenhouse Gas Storage Act 2006 that an application has been received from
Woodside Energy Julimar Pty Ltd
(ACN 130 391 365)
KUFPEC Australia (Julimar) Pty Ltd
(ACN 139 500 502)
for the grant of a pipeline licence for the conveyance of petroleum in the offshore area of Western Australia, as set out below.
A person may make a written submission to the Titles Administrator about this application within 30 days from the date of this notice.
This notice takes effect on the day in which it appears in the
Australian Government Gazette.
Made under the Offshore Petroleum and Greenhouse Gas Storage Act 2006
of the Commonwealth of Australia.
GRAEME ALBERT WATERS
TITLES ADMINISTRATOR
ON BEHALF OF THE COMMONWEALTH-WESTERN AUSTRALIA
OFFSHORE PETROLEUM JOINT AUTHORITY
ROUTE OF THE PIPELINE
The pipeline route for the system of pipes commences at the upstream connector hub face of the inline tee (ILT) of the Julimar Phase 2 (JDP2) rigid pipeline (Petroleum Pipeline Licence WA-29-PL) to the production jumper end fitting hub faces, connecting to downstream Diverless connectors at the JUB1A and JUB1B Christmas tree ends, via two infield production flowlines tied back to the JULB manifold, within a 40 m corridor (± 20 m centred on the pipelines) as described in the tables hereunder and displayed in the attached map (Attachment 1).
10” Production Flowline | ||||
Feature ID | Feature Name | UTM Zone | Easting (mE) | Northing (mN) |
1 | JULB Manifold (centroid) | 50 | 296852.0 | 7775457.0 |
2 | JULB Manifold Hub | 50 | 296852.0 | 7775451.3 |
3 | Turning Point 1 | 50 | 296852.0 | 7775308.0 |
4 | Intersection Point 1 | 50 | 296852.0 | 7775265.7 |
5 | Turning Point 2 | 50 | 296074.1 | 7775229.6 |
6 | Turning Point3 | 50 | 297891.2 | 7773569.0 |
7 | Intersection Point 2 | 50 | 297920.5 | 7773522.0 |
8 | Turning Point 4 | 50 | 297972.0 | 7773562.5 |
9 | ILT Hub | 50 | 297988.4 | 7773575.4 |
10 | JULB ILT (centroid) | 50 | 297993.0 | 7773549.6 |
JUB1A Christmas tree (XT) 8” Production Jumper | |||
Feature ID | Feature Name | Easting (mE) | Northing (mN) |
1 | JULB Manifold (centroid) | 296852.0 | 7775457.0 |
2 | JULB Manifold Hub | 296846.6 | 7775455.5 |
3 | Turning Point 1 | 269820.7 | 7775455.5 |
4 | Intersection Point 1 | 269792.1 | 7775455.5 |
5 | Turning Point 2 | 296801.9 | 7775428.6 |
6 | JUB1A XT Hub | 296807.7 | 7775412.5 |
7 | JUB1A XT (centroid) | 296809.0 | 7775409.0 |
JUB1B Christmas tree (XT) 8” Production Jumper | |||
Feature ID | Feature Name | Easting (mE) | Northing (mN) |
1 | JULB Manifold (centroid) | 296852.0 | 7775457.0 |
2 | JUB1B Manifold Hub | 296857.4 | 7775455.5 |
3 | Turning Point 1 | 296996.8 | 7775455.5 |
4 | Intersection Point 1 | 297025.7 | 7775455.5 |
5 | Turning Point 2 | 297052.5 | 7775466.1 |
6 | Turning Point3 | 300739.7 | 7776938.5 |
7 | Intersection Point 2 | 300760.2 | 7776946.7 |
8 | Turning Point 4 | 300782.2 | 7776948.6 |
9 | JUB1B XT Hub | 300897.3 | 7776958.7 |
10 | JUB1B XT (centroid) | 300901.0 | 7776959.0 |
SPECIFICATIONS
Design and Construction
The offshore pipeline must be designed and constructed in accordance with Offshore Standard DNV-OS-F101 – Submarine Pipeline Systems (Offshore Pipeline), which is incorporated in its entirety in Australian Standard AS2885.4 – Pipelines, Gas and Liquid Petroleum (Part 4: Submarine Pipelines). Specifically, the design and construction phase of the pipeline must comply with DNVGL-RP-F101
Basis of Design
The pipeline design is based on the following parameters:
Item | Item Description | Details |
1 | Outside diameter of pipe and riser | JULB flowline: 435.88 mm (10 inches) JUB1A & JUB1B flowlines: 382.48mm (8 inches) |
2 | Wall thickness of pipe inclusive of riser (only for carbon steel) | JULB flowline: 76.94 mm JUB1A & JUB1B flowlines: 89.64mm |
3 | Length | JULB flowline: 2.33km JUB1A flowline: 0.1km JUB1B flowline: 4.38km Total: 6.82km |
4 | Design life | Flowlines and Jumpers: 20 years JULB Manifold: 25 years |
5 | Pipeline Material | Flexible Corrosion Resistant Alloy steel |
6 | Pipeline and Riser Steel Grade | DNVGL-RP-F101 API 17J unbonded flexible pipe |
7 | Pipeline Specification | DNVGL-RP-F101 |
8 | Minimum yield strength of pipe steel | 415 MPa |
9 | Maximum Allowable Operating Pressure | 36.12 MPa(a) |
10 | Design Capacity | 180 MMscf/d |
11 | Maximum Design Temperature | Flowlines and Jumpers: 128°C JULB Manifold: 136°C |
12 | Minimum Design Temperature | Flowlines and Jumpers: -30°C JULB Manifold: -29°C |
13 | Operating Temperature Range | Maximum: 119.6°C Minimum: 109.6°C |
14 | Characteristics of substance proposed to be conveyed | Gas |
15 | General plans and descriptions of pump stations, tank stations or valve stations and their equipment | N/A |
16 | General plans and description of pigging facilities | N/A |
17 | Cathodic Protection | The cathodic protection system for the JULB production flowlines and jumper comprises Aluminium-Zinc-Indium anodes adjacent to the flexible end fittings.
The condition of the cathodic protection will be monitored via periodic ROV or AUV surveys. |
18 | Hydrate Management | Insulation |