AD/PC-12/22 - Electrical Power - Suppression Filters

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B06085 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Pilatus PC-12 Series Aeroplanes

 

AD/PC-12/22 Electrical Power - Suppression Filters 13/99 TX

Applicability: All Model PC-12 and PC-12/45 with Manufacturers Serial Numbers MSN 101 up to and including MSN 289.

 

Requirement: 1. Remove suppression filter (A250) part number (P/N) 524.52.12.358 and install suppression filter (A250) P/N 524.52.12.502 in accordance with Pilatus PC-12 Service Bulletin (SB) No.24-014 dated 27 October 1999.

 

Note: The new suppression filter can be positively identified by the part number and a black placard with a yellow A250 marked on it.

 

2. Perform system test in accordance with Pilatus PC-12 SB No.24-014 paragraph 3(D).

 

Note: FOCA Switzerland AD HB 99-542 refers.

 

Compliance: 1. Within the next 10 flights after the effective date of this directive.

 

2. Prior to further flight after Requirement 1.

 

This Airworthiness Directive becomes effective on 8 November 1999.

 

Background: After installation of SB 24-012 and electrical power activation, circuit breaker CB 235, which protects the GEN 2 circuit, tripped. Investigation revealed the suppression diode in the suppression filter (A250) P/N 524.52.12.358 was shorted. The diode is not capable of carrying the operational loads in this installation and can melt, resulting in a short circuit. Overheat damage to electrical wiring can result.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 