AD/PC-12/17 - Windshield Heat Wiring

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B06080 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Pilatus PC-12 Series Aeroplanes

 

AD/PC-12/17 Windshield Heat Wiring 8/99 TX

Applicability: All Model PC-12 and PC-12/45 aeroplanes with Manufacture’s Serial Numbers 101 up to and including 320, equipped with windshields Pilatus Part Number (P/N) 959.81.10.107 LH and 959.81.10.108 RH (PPG P/N NP 172121-5 LH and NP172121-6 RH.

 

Note: Affected windshields can be identified by the presence of three imbedded temperature sensors on the outboard edge of the windshield.

 

Requirement: Modify the electrical wiring in accordance with Pilatus PC-12 Service Bulletin 30- 005.

 

Note: FOCA Switzerland AD HB 99-347 refers.

 

Compliance: Before further flight.

 

This Airworthiness Directive becomes effective on 28 June 1999.

 

Background: FOCA has received several reports of overheating of the windshield de-ice system electrical power supply and temperature sensor wires located between terminal block TB152 and the windshield. This condition, if not corrected could result in total loss of electrical power in the aircraft.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.