AD/PC-12/14 - No. 2 Generator Cut-Out Relay

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B06077 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Pilatus PC-12 Series Aeroplanes

 

AD/PC-12/14 No. 2 Generator Cut-Out Relay 2/99

Applicability: Model PC-12 and PC-12/45 aeroplanes with Manufactures Serial Numbers 101 to 180 inclusive.

 

Requirement: If not previously accomplished, install a cut-out relay in the second generator electrical circuit in accordance with Pilatus Aircraft Ltd PC-12 Service Bulletin 24- 009 dated 23 September 1998.

 

Note: FOCA Switzerland AD HB 98-537 refers.

 

Compliance: Prior to 30 April 1999.

 

This Airworthiness Directive becomes effective on 25 February 1999.

 

Background: FOCA has reported occurrences of over-voltage where the over-voltage protection of the second generator was found not to automatically disconnect the second generator from the electrical system. This Directive requires the installation of a cut-out relay, controlled by the voltage control unit, which ensures that the second generator is isolated automatically should a faulty condition occur.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 