AD/P166/9 - Generator Circuit - Modification

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B05335 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Piaggio P166 Series Aeroplanes

 

AD/P166/9 Generator Circuit - Modification NK

Applicability: S/Nos. prior to 409.

 

Requirement: Remove remote reset circuit breakers fitted between the generator and the reverse circuit relay. Circuit protectors (either limiters or remote reset circuit breakers) shall be installed between the bus and the reverse current relay. Limiters, if used, need not be accessible in flight.

 

Compliance: Forthwith.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.