AD/ENST 28/18 - Alternator Field Cable Protection - Modification

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B09573 Not in force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Enstrom F-28 Series Helicopters

 

AD/ENST 28/18 Alternator Field Cable Protection - Modification 12/77

Applicability: All models.

 

Requirement: Install a circuit protective device (i.e. in line fuse or circuit breaker) in the field cable 28-3 (or 28-1 when optional overvoltage relay is fitted) as close as practical to the battery master relay connection.

 

Note: Air Navigation Order 108.32 Appendix 3, Table 6 provides a suitable cable and circuit protector co-ordination chart.

 

Compliance: 1. Before issue of Certificate of Airworthiness on all aircraft certificated after 28 February 1978.

 

2. All other aircraft within 100 hours time in service after 28 February 1978.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.