AD/ELECT/58 - SAFT 1606-1 Batteries

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B09432 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 107 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Electrical Equipment

 

AD/ELECT/58 SAFT 1606-1 Batteries 2/91

Applicability: All SAFT 1606-1 batteries equipped with temperature probes, and fitted to aircraft or held as spares.

 

Note: Aircraft known to be fitted with this type of battery include, but are not limited to Aerospatiale AS 350 and AS 355 helicopters.

 

Requirement: Verify the presence of the battery shunt (jumper) between terminals 2 and 3 of the female plug on the battery temperature probe cable. If the shunt is missing, install a shunt P/No 161-211 and ensure correct operation of the temperature probe system.

 

Note: DGAC AD 90-198-056(B) also refers.

 

Compliance: 1. For batteries fitted to aircraft: within 50 hours time in service after 21 February 1991.

 

2. For uninstalled batteries: before installation in an aircraft.

 

Background: Advice has been received that the temperature probe shunt may be not installed or missing on some SAFT 1606-1 batteries which may result in nil operation of the temperature sensing system, and therefore failure to detect a potentially dangerous overheated battery condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.