AD/ELECT/43 - J.E.T. Emergency Power Supply - Inspection/Modification

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B09420 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 107 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Electrical Equipment

 

AD/ELECT/43  J.E.T. Emergency Power Supply - Inspection/Modification

Applicability: All J.E.T. power supplies. Model PS835 series.

 

Requirement: 1. If the installation incorporates a panel located battery test switch, install a temporary placard near the test switch which reads as follows:

 

“To test emerg pwr supply

 

  1. Disregard emerg pwr sw test position.

 

2.    A/C master/batt sw - off.

 

3.    Emerg pwr sw - on.

 

4.    Ck operation of accessory/instr”.

 

2. Modify as required by JET Alert SB A-SB501-1228-7. FAA AD 82-21-04 Amendment 39-4475 refers.

Compliance: For Para. 1 - Within 100 hours time in service after 31 March 1983. For Para. 2 - Within 200 hours time in service after 31 March 1983.

Background: To prevent false indication that emergency power is available.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


3/83

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.