COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Eurocopter AS 350 (Ecureuil) Series Helicopters

 

AD/ECUREUIL/41 Battery Thermal Sensor Connector 6/88

Applicability: All AS 350 Helicopters.

 

Requirement: Verify the presence of a shorting link between pins 2 and 3 of the battery thermal sensor receptacle 26P.

 

Compliance: Prior to 16 July 1988.

 

Background: The battery overheat warning light is connected to sockets 1 and 2 of plug 26P, whilst the thermal sensor which activates the light is connected to pins 1 and 3 of the mating receptacle 26P. A shorting link between pins 2 and 3 of the receptacle completes the circuit. The RAAF have advised that in one aircraft this shorting link was missing thus preventing any battery overheat being indicated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 