AD/CESSNA 310/22 Amdt 1 - Rerouting of Suppressor Cable - Modification

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B08149 Not in force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Cessna 310 Series Aeroplanes

 

AD/CESSNA 310/22

Amdt 1


Rerouting of Suppressor Cable - Modification


5/70

 

Applicability: All model 310I, J, K, L and N.

 

Requirement: 1. Disconnect Type S5508 Suppressor cable (P45) from battery ammeter shunt located in the left hand junction box.

 

2.    Reroute cable (P45) and connect it to the DC bus through a 10 amp circuit breaker.

 

Note: If no spare circuit breaker position is available it may be necessary to connect the cable through an existing 10 amp circuit breaker (i.e. Cabin Heat/Hour Indicator).

 

3.    Fit appropriate decal to circuit breaker panel to identify suppressor circuit breaker). Compliance:              Within 100 hours time in service after 29 May 1970.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.