AD/CESSNA 206/44 - Electrical Power Distribution and Control

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B05249 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Cessna 206 Series Aeroplanes

 

AD/CESSNA 206/44 Electrical Power Distribution and Control 8/86

 

Applicability:

All Cessna Model U206G and FAA STC SA2353NM (Soloy

numbers:

TU206G aeroplanes modified in accordance with U.S. Turbine Conversion) with the following serial

 

CESSNA SERIAL NUMBER

SOLOY DATA PLATE NO

 

U20603989

763-013

 

U20604266

763-001

 

U20604287

763-003

 

U20604881

763-014

 

U20605232

763-005

 

U20605567

763-002

 

U20605584

763-015

 

U20605745

763-008

 

U20605936

763-006

 

U20606065

763-007

 

U20606227

763-004

 

U20606381

763-011

 

U20606628

763-010

 

U20606768

763-012

 

U20606816

763-009

Requirement: 1. Replace the voltage regulator in accordance with Soloy Service Bulletin 04-763. 2. For aeroplanes with S/Nos. U20604266, U20604287, U20605232, U20605567,

U20605745, U20605936, U20606065 and U20606227, modify the electrical system circuit breaker installation in accordance with Soloy Service Bulletin 02- 763.

 

Note: FAA AD 86-11-07 Amendment 39-5324 refers.

 

Compliance: For Para 1: Within 100 hours time in service after 31 August 1986. For Para 2:              Within 200 hours time in service after 31 August 1986.

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 

Background: 1. The existing voltage regulator installation has been shown to interfere with the ADF system such as to cause erroneous bearing information to be displayed.

 

2. The engine start circuit and the auto feather circuit are at present connected to the same circuit breaker. Opening this circuit breaker by an electrical fault or by pilot action will render both circuits inoperative.

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.