COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Cessna 150, F150, 152 & F152 Series Aeroplanes
AD/CESSNA 150/22
Amdt 2
Alternator Field Circuit Breaker 12/78
Applicability: All models Cessna 150J, 150K, A150K, 150L, A150L, 150M A150M, 152 and A152.
Reims/Cessna F150J, F150K, FA150K, F150L, FA150L, FRA150L, F152 and FA152.
Requirement: Replace the alternator field automatic reset type circuit breaker with a manual reset type circuit breaker or fuse of a similar rating to that removed.
Compliance: Before issue of C of A on all affected aircraft
- After 31 December 1978.
2. All other aircraft within 100 hours time in service after 31 December 1978.
Aircraft complying with a previous issue of this Directive satisfy compliance with this issue.