AD/BELL 206/88 - Battery Relay Diode Assembly P/N 30-037-13 - Replacement

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B04537 Not in force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 

Bell Helicopter Textron Canada (BHTC) 206 and Agusta Bell 206 Series Helicopters

 

AD/BELL 206/88 Battery Relay Diode Assembly P/N 30-037-13 - Replacement

Applicability: All model Bell 206L-1 with S/Nos. 45154 to 45610. Document:  Bell Alert SB No. 206L-81-18 Rev. “A”.

Compliance: Within 100 hours time in service after 30 June 1981.


6/81

 

Background:  There have been several battery relay diode failures reported recently from various operators. This type of failure can and has resulted in burned wiring and smoke in the associated electrical system.