AD/BEECH 400/5 - Main Circuit Breaker Panel

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B03932 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Beechcraft 400 Series Aeroplanes

 

AD/BEECH 400/5 Main Circuit Breaker Panel 1/94

DM

 

Applicability: Model 400A aircraft with serials numbers RK-45 and RK-49 through RK-77 inclusive.

 

Requirement: Action in accordance with Beechcraft Mandatory Service Bulletin 2520 dated August 1993 and Beechcraft Service Communique 400-101 dated July 1993.

 

Note: FAA AD 93-20-01 Amdt 39-8708 refers.

 

Compliance: Within 25 hours time in service from 17 November 1993.

 

Background:  Beechcraft have advised of anomalies in the main circuit breaker panel wiring and that there is a possibility for an electrical short to occur. Compliance with this Directive will decrease the probability of an electrical short causing fire and smoke in the cockpit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 