AD/BAL/14 - Fast Flow Restrictor Valves

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B03552 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Hot Air Balloons

 

AD/BAL/14 Fast Flow Restrictor Valves 11/95 DM

Applicability: All hot air balloons.

 

Requirement: Inspect LP gas cylinders for fitment of fast flow restrictor valves and remove if fitted.

 

Note: Inspection of LP cylinders for fitment of restrictor valves may be accomplished by an AS2337- approved gas cylinder test station or by an operational check of each cylinder, with burner alight.

 

Compliance: Before further flight. Thereafter, following any maintenance, or inspection for date stamping.

 

Background:  There have been cases reported of fast flow restrictor valves being fitted internally to LP gas cylinders during maintenance. Because a balloon burner uses fuel within the operating range of the fast flow restrictor valve, a serious accident could result.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 