COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Hot Air Balloons
AD/BAL/13 Portable Fire Extinguisher 13/94
Applicability: All Hot Air Balloons.
Requirement: 1. If not already accomplished install a dry powder type or a BCF vapourizing-liquid type portable fire extinguisher of at least 1 kg capacity, complying with Australian Standard AS 1841 or equivalent.
2. Maintain portable fire extinguishers in accordance with the manufacturer’s recommended schedule or Australian Standard AS 1851.1.
Note: A dry powder type extinguisher is the preferred type.
Compliance: 1. Before issue of a certificate of airworthiness or before 10 May 1995.
2. In accordance with the manufacturer’s schedule or that given in AS1851.1.
Background: A fire extinguisher is considered an essential safety item in a hot air balloon in the event of a gas leak with the burner alight.
Overview
The Civil Aviation Regulations 1998, specifically under Part 39 - 105, mandate the installation and maintenance of portable fire extinguishers in all hot air balloons. This regulation, enacted by the Commonwealth of Australia, aims to address the critical safety concerns associated with operating hot air balloons, particularly the risk of fire due to gas leaks while the burner is alight. The policy objective is to ensure that hot air balloons are equipped with essential safety equipment to mitigate potential fire hazards, thereby enhancing the safety of operations. Compliance with these requirements is crucial for the certification of airworthiness, and failure to adhere to the specified standards could result in the denial of a certificate of airworthiness.
The regulation stipulates the installation of either a dry powder type or a BCF vapourizing-liquid type portable fire extinguisher with a minimum capacity of 1 kg, compliant with Australian Standard AS 1841 or equivalent. Furthermore, it mandates that these extinguishers be maintained in accordance with the manufacturer's recommended schedule or Australian Standard AS 1851.1. This directive underscores the importance of regular maintenance to ensure the effectiveness of fire extinguishers, thereby reinforcing the overall safety framework for hot air balloon operations.
Scope and Application
The Civil Aviation Regulations 1998, specifically Part 39 - 105, mandates the Airworthiness Directives concerning hot air balloons, detailing the requirement for the installation and maintenance of portable fire extinguishers. This regulation applies to all hot air balloons, ensuring that each must be equipped with a dry powder type or a BCF vapourizing-liquid type portable fire extinguisher with a minimum capacity of 1 kg, adhering to Australian Standard AS 1841 or equivalent. The directive further mandates that these fire extinguishers be maintained in accordance with the manufacturer’s recommended schedule or Australian Standard AS 1851.1, with a preference for dry powder type extinguishers due to their effectiveness. The requirement to comply with these standards is imperative either before the issuance of a certificate of airworthiness or by 10 May 1995, underscoring the critical nature of these safety measures in mitigating the risks associated with hot air balloon operations. This regulation extends across the Commonwealth of Australia, ensuring consistent safety standards are applied nationwide.
Key Provisions
The Civil Aviation Regulations 1998, under Part 39, Section 105, mandate the installation and maintenance of portable fire extinguishers in hot air balloons, as outlined in AD/BAL/13. This applies to all hot air balloons (AD/BAL/13). The regulation requires that each hot air balloon must be equipped with either a dry powder type or a BCF vaporizing-liquid type portable fire extinguisher of at least 1 kg capacity, adhering to Australian Standard AS 1841 or its equivalent (AD/BAL/13.1). The preferred type of extinguisher is the dry powder type (AD/BAL/13 Note). Furthermore, these extinguishers must be maintained according to either the manufacturer's recommended schedule or Australian Standard AS 1851.1 (AD/BAL/13.2).
The obligations imposed by the regulations require operators and owners of hot air balloons to ensure that the specified fire extinguishers are installed and maintained appropriately. This involves checking the presence of a compliant fire extinguisher before any certificate of airworthiness is issued or before 10 May 1995, depending on the circumstances (AD/BAL/13.1 and AD/BAL/13.3). Maintenance must align with the manufacturer's schedule or the guidelines provided in AS 1851.1 (AD/BAL/13.2).
Failure to comply with these provisions can result in significant consequences. Operators and owners who do not adhere to the requirements may face civil penalties, as outlined in the Civil Aviation Act 1988. Non-compliance could potentially lead to the revocation of the airworthiness certificate, grounding of the balloon, or other regulatory actions deemed necessary by the Civil Aviation Safety Authority (CASA). The exact penalties and consequences depend on the severity and frequency of the breach, but they can include fines and other enforcement actions as stipulated by the relevant legislation.