AD/B747/77 - APU Fire Detection

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B03255 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Boeing 747 Series Aeroplanes

 

AD/B747/77 APU Fire Detection 5/90

Applicability: All model Boeing 747-400 series aeroplanes as listed in Boeing SB 747-26-2135 Revision 1, or later revision.

 

Requirement: Modify the APU electrical power circuitry in accordance with Boeing SB 747-26- 2135 Revision 1 or later revision.

 

Compliance: Prior to 17 August 1990.

 

Background: In the current configuration if the main battery switch is turned off whilst the APU is operating, power to the APU fire detection system is removed. The APU goes through a 60 second cool down cycle with the fire detection system inoperative.

Compliance with this AD is required to correct this unacceptable condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.