AD/B737/39 - APU Fire Detector Element

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B02938 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Boeing 737 Series Aeroplanes

 

AD/B737/39 APU Fire Detector Element 7/90

Applicability: All model 737 series aircraft equipped with Walter Kidde APU fire detection systems.

 

Requirement: Inspect to ensure a Walter Kidde fire detector element is installed in the APU compartment. This inspection may be performed by viewing through the APU cooling air exhaust outlet. The Walter Kidde element is protected by a perforated shield surrounding the length of the element. If the perforated shield is not seen, open the lower APU shroud and verify that for 737-300 and 737-400 series aircraft, the fire detector element installed is Boeing P/N 10-61096-316 / Walter Kidde P/N 894481, and for 737-100 and 737-200 series aircraft, the fire detector element installed is Boeing P/N 10-62061-6 or P/N 10-61096-116.

 

Compliance: Prior to 19 July 1990.

 

Background:  Boeing has advised that several aircraft with Walter Kidde APU fire detection systems were found to have a Systron-Donner fire detector element fitted instead of the correct Walter Kidde element. This would result in a positive flight deck fire detector test even though the system would not have detected an actual fire.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.