AIRWORTHINESS DIRECTIVE

For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.1 (1) of CAR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.

 

Boeing 737 Series Aeroplanes

 

AD/B737/173 Power Distribution Panels 2/2002

 

Applicability: Model 737-600, -700, and -800 series aeroplanes, equipped with power distribution panels (PDP) bearing any of the following Boeing part numbers, as listed in the "Existing Part Number'' column of the table under paragraph 2.E., "Existing Parts Accountability,'' of Boeing Service Bulletin (SB) 737-24-1128, dated 29 April 1999.

 

S281A601-1000

S281A601-1074

S281A601-2003

S281A601-2199

S281A601-1001

S281A601-1108

S281A601-2007

S281A601-2216

S281A601-1002

S281A601-1110

S281A601-2032

S281A601-2217

S281A601-1003

S281A601-1111

S281A601-2038

S281A601-2220

S281A601-1018

S281A601-1120

S281A601-2039

S281A601-2222

S281A601-1020

S281A601-1122

S281A601-2055

S281A601-2226

S281A601-1045

S281A601-1128

S281A601-2057

S281A601-2228

S281A601-1054

S281A601-1162

S281A601-2109

S281A601-2234

S281A601-1055

S281A601-1216

S281A601-2110

S281A601-2275

S281A601-1056

S281A601-2001

S281A601-2111

S281A601-2434

S281A601-1057

 

 

 

 

Requirement: 1. Unless previously accomplished, perform a one-time general visual inspection to verify proper installation of the power feeder terminals and associated hardware located in power distribution panels (PDP) P91 and P92, in accordance with the following procedures:

 

Using a flashlight, inspect each of the six power feeder terminals by looking into the access holes located in the plastic cover of the rigid bus assembly. The holes are located on the aft face of PDPs P91 and P92. (Refer to the Boeing 737-600, -700, -800, -900 Aeroplane Maintenance Manual (AMM), Section 24-21-71, Page 402, Figure 401 (Sheet 1), for the location of PDP P91 and P92.) On PDP P91, the holes are adjacent to terminal blocks TB5001 and TB5002. On PDP P92, the holes are adjacent to terminal blocks TB5005 and TB5006. There are a total of six holes per PDP. (Refer to the Boeing 737- 600, -700, -800, -900 AMM, Section 24-21-71, Page 403, Figure 401 (Sheet

2), for the location of the access holes on the PDPs.) Note that although each PDP has nine power feeder terminals, only the six terminals adjacent to the access holes require inspection.

 

Verify that the power feeder terminal is properly installed and held in place on the busbar by the No. 8 socket head cap screw, and verify that the cap screw is inserted into the hole in the terminal. For the proper power feeder terminal and screw buildup, refer to the Boeing 737-600, -700, -800, -900 AMM,

Chapter 24-21-71, Page 405, Figure 401 (Sheet 4). The subject power feeder terminal is identified as item (7) and the cap screw as item (12).

 

This visual inspection does not require loosening or removing any fasteners. The inspection may require looking through the access hole at a slight angle to see the terminal clearly. The terminal can be identified by its shiny metal finish; the current transformer behind the terminal block is made of plastic with a flat black finish.

 

Note 1: For the purposes of this Directive, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, flashlight, or drop-light, and may require removal or opening of access panels or doors. Stands, ladders, or platforms may be required to gain proximity to the area being checked.''

 

2.        If the requirement 1 visual inspection reveals that the power feeder terminal and No. 8 socket head cap screw are not assembled as shown in Boeing 737-600, - 700, -800, -900 AMM, Section 24-21-71, Page 405, Figure 401 (Sheet 4), replace the rigid bus assembly with a new assembly, in accordance with the procedures specified in Boeing 737-600, -700, -800, -900 AMM, Section 24-21-22

 

3.        Perform a torque check of the attachment screws of the power feeder terminals in accordance with the procedures specified in Boeing Maintenance Tip 737 MT

24-003, dated 14 May 1998.

 

4.        Replace the PDP rigid bus assemblies with new assemblies having the same part numbers as the removed assemblies, in accordance with the procedures specified in Boeing 737-600, -700, -800, -900 AMM, Chapter 24-21-22.

 

Replacement of existing PDP rigid bus assemblies with new, improved PDP rigid bus assemblies having part number 1032181-2 or 1032185-2, as applicable, according to Boeing Service Bulletin 737-24-1128, dated 29 April 1999, constitutes optional terminating action for the Requirements of this Directive.

 

Note 3: FAA AD 2001-22-11 Amdt 39-12490 and AD 99-08-03 Amdt 39-11107 refer.

 

Compliance: For Requirement 1 - Within 30 days after the effective date of this Directive.

 

For Requirement 2 - Prior to further flight, following the Requirement 1 inspection.

 

For Requirement 3 - Initially concurrent with Requirement 1 and thereafter at intervals not to exceed 1,000 hours time in service (TIS), in accordance with the maintenance tip, until replacement of existing PDP rigid bus assemblies with new, improved PDP rigid bus assemblies having part number 1032181-2 or 1032185-2, as applicable, according to Boeing SB 737-24-1128 is accomplished.

 

For Requirement 4 - Within 1,000 hours TIS after accomplishment of the eighth Requirement 3 torque check and thereafter within 1,000 hours TIS after every subsequent eighth torque check, until replacement of existing PDP rigid bus assemblies with new, improved PDP rigid bus assemblies having part number 1032181-2 or 1032185-2, as applicable, according to Boeing SB 737-24-1128 is accomplished.

 

This Airworthiness Directive becomes effective on 21 February 2002.

 

Background: This Directive initially requires an inspection of the PDPs to verify proper installation of the power feeder terminals together with associated hardware and, if necessary, corrective actions. The Directive also requires repetitive torque checks of the terminal attachment screws and repetitive replacement of the PDP rigid bus assembly with a new assembly until optional terminating action is accomplished.

 

These actions are intended to prevent overheating, melting, and subsequent failure of the power feeder terminals, which could result in increased risk of fire and the loss of electrical power from the associated alternating current power source.


 

Eugene Paul Holzapfel

Delegate of the Civil Aviation Safety Authority 14 January 2002

 

 

 

 

 

 

 

 

 

 

 

 

 


The above AD is notified in the Commonwealth of Australia Gazette on 30 January 2002.

Overview

The Civil Aviation Safety Authority (CASA) issued Airworthiness Directive AD/B737/173 on 14 January 2002 under subregulation 39.1(1) of the Civil Aviation Regulations 1998 (CAR 1998). This directive applies to Boeing 737-600, -700, and -800 series aeroplanes equipped with specific power distribution panels (PDP). The directive was enacted to address the potential for overheating, melting, and subsequent failure of power feeder terminals, which could result in increased fire risk and loss of electrical power. The directive mandates a series of inspections and corrective actions, including a one-time visual inspection, replacement of rigid bus assemblies, and repetitive torque checks, to ensure the safe installation of the power feeder terminals and associated hardware. Compliance with this directive is required within specified timeframes to maintain airworthiness standards. This Airworthiness Directive was issued by CASA to address safety concerns related to the power distribution panels in certain Boeing 737 series aeroplanes. The directive aims to mitigate the risk of terminal overheating and failure, which could lead to electrical issues and increased fire hazards. The policy objective is to ensure the safe and reliable operation of affected aircraft by enforcing specific maintenance actions. CASA, as the delegate for the Civil Aviation Safety Authority, issued this directive to enforce compliance with airworthiness standards and to enhance the safety of the aviation industry.

Scope and Application

The Airworthiness Directive F2006B02877, issued under the Civil Aviation Regulations 1998, applies to specific models of the Boeing 737 Series aeroplanes, namely the 737-600, -700, and -800 series, which are equipped with power distribution panels bearing specified part numbers. This directive pertains to the inspection and corrective actions required for the power feeder terminals and associated hardware in the power distribution panels P91 and P92. The directive is enforced by the Civil Aviation Safety Authority (CASA) and its delegate, Eugene Paul Holzapfel, and it mandates a visual inspection to verify proper installation, replacement of rigid bus assemblies if necessary, and periodic torque checks of attachment screws. The directive applies nationally across Australia, as it is a Commonwealth regulation. There are no stated exclusions or exemptions within the text, but the directive may be extended or restricted through subordinate instruments. The directive became effective on 21 February 2002, and compliance timelines are provided for each requirement, with an initial inspection to be conducted within 30 days of the directive's effective date.

Key Provisions

The main sections of the Airworthiness Directive (AD) address the requirements for Boeing 737-600, -700, and -800 series aeroplanes equipped with specific power distribution panels (PDP). The AD (paragraph 2) specifies the models and parts that apply to the directive, listing the Boeing part numbers that must be inspected. The requirement section (paragraph 3) outlines the actions that must be taken, which include a visual inspection of the power feeder terminals and hardware in PDPs P91 and P92, replacing the rigid bus assembly if necessary, and performing torque checks and replacements at regular intervals. Compliance with these requirements is expected within specific timeframes and intervals, detailed in paragraph 4. The obligations imposed by this AD require operators of Boeing 737-600, -700, and -800 series aeroplanes to conduct a one-time general visual inspection of the specified power distribution panels, ensuring the power feeder terminals are correctly installed. If the inspection reveals improper installation, the rigid bus assembly must be replaced. Additionally, operators must perform torque checks of the terminal attachment screws and replace the PDP rigid bus assemblies at specified intervals until they are replaced with new, improved assemblies as per Boeing Service Bulletin 737-24-1128. Failure to comply with the AD can result in significant safety risks, including the potential for overheating, melting, and subsequent failure of the power feeder terminals, which could lead to increased fire risk and loss of electrical power. While the AD does not explicitly state penalties for non-compliance, failure to adhere to airworthiness directives can result in severe consequences under the Civil Aviation Safety Authority (CASA) regulations, potentially including fines, aircraft grounding, and other enforcement actions to ensure compliance and maintain aviation safety standards.