AD/A320/36 Amdt 2 - Passenger Door Lower Connection Link Bushes

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B01926 Not in force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Airbus Industrie A319, A320 and A321 Series Aeroplanes

 

AD/A320/36

Amdt 2


Passenger Door Lower Connection Link Bushes 10/94

 

Applicability: All models without Modification 22422 (SB A320-52-1027) embodied. Requirement:               Unless already accomplished, action in accordance with:

  1. Airbus Industrie AOT 52-04 Revision 1 dated 12 October 1993, or Airbus Industrie SB A320-52-1047, and

 

2.    Airbus Industrie S.B. A320-52-1027, limited to the installation of kit number 521027A02 on all doors.

 

Note: DGAC AD 93-207-048(B) R1 refers.

 

Compliance: 1. Within 450 hours time in service after 19 January 1994 and thereafter at intervals not exceeding 900 hours’ time in service until modified.

 

2. Within 3 500 hours time in service after 19 January 1994.

 

The compliance of the original AD remains unchanged, this amendment is effective 15 September 1994.

 

Background: During an emergency evacuation, one of the passenger doors jammed in a near closed position against the fuselage structure. Subsequent investigation found that the lower connecting link bush had migrated. Amendment 1 corrects the repeat inspection compliance time. Amendment 2 revises the Requirement references, no further actions are required.

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions

Sourced from the Federal Register of Legislation at 26 August 2026. For the latest information on Australian Government law please go to https://www.legislation.gov.au.