AD/A320/28 - Pylon Fuel Return Line Connection and Pylon Sealant Integrity

Administered by Department of Infrastructure, Transport, Regional Development, Communications, Sport and the Arts

Legislation au F2006B01919 In force Legislative Instrument

Legislation content

COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY

SCHEDULE OF AIRWORTHINESS DIRECTIVES

 


Airbus Industrie A319, A320 and A321 Series Aeroplanes

 

AD/A320/28 Pylon Fuel Return Line Connection

and Pylon Sealant Integrity


2/93

DM

 

Applicability: Serial numbers 002 to 180, 183 to 194, 196 to 315, 317 to 321, 323 to 325 and 328 to

334 inclusive.

 

Requirement: Action in accordance with Airbus Industrie AOT 28-04 Revision 1 dated 9 September 1992.

 

Note: DGAC AD 92-228-037(B) of 28 October 1992 refers.

 

Compliance: Within 500 flying hours from 1 Jan 1993.

 

Background: During the final phase of a landing, the Number 2 engine fire warning of an aircraft illuminated twice for several seconds. The engine was shut down normally. A small fire fed by hot fuel from a loose return line connection had occurred on top of the engine. This fuel had passed through deteriorated sealant in the pylon drain system on to the engine where it ignited.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interactions

Authorises

All Versions